When a flashover occurs from a fire in a building compartment, the fire intensifies explosively and changes from a fuel-controlled fire to a ventilation-controlled fire. As a result, flames and unburnt gas are ejected from openings. The ejected unburned gas reacts violently with external oxygen to form a large-scale ejected flame, which causes the fire to expand to the upper layer. Moreover, the radiation of extreme heat to neighboring buildings contributes to fire spreading between buildings. In this study, a quantitative evaluation process was established to evaluate the thermal effect of radiant heat generated from an open fire on the exterior materials of facilities, assuming a fully developed fire.