Abstract

This paper describes the methodology implemented by the Institute for Nuclear Safety and Protection (IPSN) to carry out the Fire Probabilistic Safety Assessment (Fire PSA) for French 900 MWe pressurised water reactors. The initial results obtained are presented. Additional research and development activities are indicated which IPSN carried out or decided to perform in order to reduce the amount of uncertainty associated with the data or to confirm hypotheses that can impact significantly the study results.