Abstract
PurposeEarthquake tremors not only increase the chances of fire ignition but also hinder the fire-fighting efforts due to the damage to the lifelines of a city. Most of the international codes have independent recommendations for structural safety against earthquake and fire. However, the possibility of a multi-hazard event, such as fire following an earthquake is seldom addressed.Design/methodology/approachThis paper presents an experimental study of Reinforced Concrete (RC) columns in post-earthquake fire (PEF) conditions. An experimental approach is proposed that allows the testing of a column instead of a full structural frame. This approach allows us to control the loading and boundary conditions individually and facilitates the testing under a variety of these conditions. Also, it allows the structure to be tested until failure. The role of parameters, such as earthquake intensity, axial load ratio and the ductile detailing of the column on the earthquake damage and subsequently the fire performance of the structure, is studied in this research. Six RC column specimens are tested under a sequence of quasi-static earthquake loading, followed by combined fire and axial compression loading conditions.FindingsThe experiment results indicate that ductile detailed columns subjected to 4% or less lateral drift did not lose significant load-carrying capacity in fire conditions. A lateral drift of 6% caused significant damage to the columns and reduced the load-carrying capacity in fire conditions. The level of the axial load acting on the column at the time of earthquake loading was found to have a very significant effect on the extent of damage and reduction in column load capacity in fire conditions. The columns that were not detailed for a ductile behavior observed a more significant reduction in axial load carrying capacity in fire conditions.Research limitations/implicationsThis study is limited to columns of 230 mm size due to the limitations of the test setup. The applicability of these findings to larger column sections needs to be verified by developing a numerical analysis methodology and simulating other post-earthquake-fire tests available in the literature.Originality/valueThe experimental procedure proposed in this paper offers an alternative to the testing of a complete structural frame system for PEF behavior. In addition to the ease of conducting the tests, the procedure also allows much better control over the heating, structural loading and boundary conditions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.