Abstract

BackgroundLaser surgery is an attractive alternative to other means of section device in terms of tissue inflammation and interaction, which has been extensively used in human and veterinary medicine. Although accidental ignition during laser surgeries is sporadically reported in human medical literature, to the authors’ knowledge this is the first report regarding laser-dependent fire ignition during surgery in veterinary medicine.Case presentationTwo rodents, a 13-month old, 27-gram, male pet mouse (Mus musculus) and a 1-year old, female Russian hamster (Phodopus sungorus), underwent surgical removal of masses with diode laser. During the surgical procedures fires ignited from the face masks. The mouse presented severe burns on the head and both forelimbs, it was hospitalized and approximately 2 months after surgery burns were resolved. The hamster presented severe burns on the face and the proximal regions of the body. At 72 hours from the accident the hamster was euthanized.ConclusionThe present report suggests that fire ignition is a potential life-threatening complication of laser surgery in non-intubated rodents maintained under volatile anesthesia. High oxygen concentrations, the presence of combustible, and the narrowness of the surgical field with the face mask during laser surgery on rodents are risk factors for fire ignition.

Highlights

  • Laser surgery is an attractive alternative to other means of section device in terms of tissue inflammation and interaction, which has been extensively used in human and veterinary medicine

  • The present report suggests that fire ignition is a potential life-threatening complication of laser surgery in non-intubated rodents maintained under volatile anesthesia

  • Laser surgery is an attractive alternative to other means of section device in terms of tissue inflammation and interaction [1], which has been extensively used in human [2,3,4,5] and veterinary medicine [6,7,8]

Read more

Summary

Conclusion

The present report suggests that fire ignition is a potential life-threatening complication of laser surgery in non-intubated rodents maintained under volatile anesthesia. The presence of combustible, and the narrowness of the surgical field with the face mask during laser surgery on rodents are risk factors for fire ignition

Background
Discussion
Findings
Conclusions
35. Longley LA

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.