Abstract

The paper gives a quantitative description of the fire development in large tunnel fires and simple analytical expressions to calculate the heat release rate (HRR), time to reach the maximum HRR and the fire duration in fuel-controlled tunnel fires. If knowing the total heat content and the maximum HRR, there will be only one parameter to vary, the parameter n from the original work by Numajiri and Furukawa [1]. Comparison to experimental data from large-scale tunnel fires is presented in order to see the applicability of the mathematical expressions for tunnel fires. Investigators of large tunnel fire accidents and researchers can use the mathematical expressions given in order to reconstruct the HRR development. These equations can also be applied when there is a need for analytical descriptions of HRR of free burning fires.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.