Abstract
A fire development analysis of three series of train carriage fire tests in different scales was carried out. These train carriage fire tests included 1:10 model scale tests, 1:3 model scale tests and 1:1 full scale tunnel tests. The heat release rate (HRR) correlations between different scales of carriage fire tests were carefully investigated. The mechanism of fire development is very similar in different scales of tests involving fully developed fires. After the critical fire spread, the fire travelled along the carriage at an approximately constant speed. The maximum heat release rate obtained for a fully developed fire is dependent on the ventilation conditions and also the type and configuration of the fuels, and a simple equation has been proposed to estimate the maximum heat release rate. A global correction factor of the maximum heat release rate is presented and examined.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.