Abstract
Abstract This paper reports an investigation into the behaviour of high strength SCC (self-consolidating concrete) filled steel tubular stub columns exposed to standard fire. A series of tests were carried out to obtain the temperature distribution, axial deformation, limiting temperature of steel and fire endurance of the SCC filled steel tubular stub columns. In addition, a finite element analysis (FEA) model was proposed and used to simulate the fire behaviour of the columns. In the FEA modeling, a sensitivity study was conducted to determine the concrete fracture energy and the contact property of the steel and concrete interface. The verified FEA model was used to analyse the structural behaviour of the columns under fire exposure, such as strain, stress, the load sharing between the steel tube and concrete and local buckling of the steel tube, to gain an insight into the failure mechanism of the columns.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.