Abstract
This paper deals with the influence the finite heat capacity of the matrix of regenerators on the performance of cryocoolers. The dynamics of the various parameters is treated in the harmonic approximation focussing on the finite heat-capacity effects, real-gas effects, and heat conduction. It is assumed that the flow resistance is zero, that the heat contact between the gas and the matrix is perfect, and that there is no mass storage in the matrix. Based on an energy-flow analysis, the limiting temperature, temperature profiles in the regenerator, and cooling powers are calculated. The discussion refers to pulse-tube refrigerators, but it is equally relevant for Stirling coolers and GM-coolers.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.