The authors have used the BERSAFE finite element computer program to model an equal diameter branch pipe intersection of mean diameter/thickness ratio 24.5. Previous results for internal pressure and the two in-plane bending moments are augmented by the present results for the two out-of-plane and the two twisting moment load categories. The predicted stresses are compared with results from tests on a 254 mm (10 inch) diameter welded branch junction, and also with the values from the current UK power piping code BS 806.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.