Abstract

This paper reports the results of finite element analysis representing the sealing performance tests on the slip-on type pipe flange connections for 8 inch and 16 inch. The flange connections are subjected to internal pressure and bending moment. Internal pressure is applied by helium gas and the bending moment is loaded through 4 points bending equipment. Gas leak rates are measured by pressure decay method. During the test, the variations in the axial bolt force are monitored for all the bolts by strain gages. The pipe stress at the junction of pipe and flange is also measured. Finite element analysis simulates the tests and the simulated results are compared with the measured data. Then the behaviors of the slip-on type flange connections under internal pressure and bending moment as well as the sealing performance are clarified by the experiment and the finite element simulation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.