Abstract

Using appropriately modified magnetization curves for each element of creep-damaged material, a finite element calculation has been carried out to simulate magnetic detection of non-uniform creep damage around a seam weld in a 2.25 Cr 1 Mo steam pipe. The magnetization curves for the creep-damaged elements were obtained from an earlier model for the magnetic effect of a uniformly creep-damaged material as given by Chen, et al. In the finite clement calculation, a magnetic C-core with primary and secondary coils was placed with its pole pieces flush against the specimen in the vicinity of the weld. The secondary emf was shown to be reduced when creep damage was present inside the pipe wall at the cusp of weld and in the vicinity of the cusp. The C-core detected the creep damage best if it completely spanned the weld seam width. Also, the current in the primary needed to be such that the C-core was not magnetically saturated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.