Abstract

The article presents a calculation of rubber-metal vibration isolators with five holes of different diameters using a software package that implements the finite element method. A comparative analysis of the Eigen frequencies of rubber-metal vibration isolators with five holes (one in the center, 4 symmetrically at the corners) and without holes is presented. Finite element models of a rubber-metal vibration isolator with and without holes are modeled, and their characteristics are analyzed. The results show that vibration isolators with several symmetrically located holes have several advantages in a number of parameters to vibration isolators without holes, and, therefore, can be used for vibration isolation of buildings, especially in the case of delayed installation of vibration protection.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.