Abstract
This work develops a general finite-element (FE) model for synchronous machines. A two-dimensional, nonlinear, time-stepped finite-element simulation of a line-to-line short circuit is performed on a large salient-pole synchronous generator with multiple rotor circuits under no-load conditions. The measurements for model assessment are recorded on a 40-pole, 13.75-MVA hydrogenerator at Hydro-Quebec Rapides-des-Quinze generating station. The obtained results attest to the effectiveness of FE numerical model in performance prediction of large hydrogenerators including the saturation phenomenon.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.