Abstract
Buried flexible pipes are allowed to deflect up to 2–5% of the pipe diameter, which can become problematic for the connected direct-bury, large-diameter butterfly valves. The complex behavior of the pipe–valve–soil system makes it difficult to predict the deflection of the pipe/valve system. In the absence of field/experimental studies, the application of finite element analysis (FEA) seems necessary to predict deflection and stresses and to avoid potential downtime associated with disruption of service. This paper described the FEA of a large-diameter pipe–valve system, with different backfills under gravity, overburden, and internal pressure loads. The effects of modeling different components of the system (e.g., flanges, bearing housing, gate disc, etc.) were described and investigated. The goal of this study was to provide insight into the design and installation of direct-bury pipe–valve systems and evaluate current installation methods in the absence of guidelines. In addition, the level of modeling details required for FEA to yield accurate results was discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.