Abstract

This research presents a study on the numerical simulation of the structural behavior of bolted shear connectors used as force transfer device in concrete-filled composite columns. The numerical model was developed in ABAQUS software, using the constitutive model named Concrete Damaged Plasticity. In the study, the influence of different concrete stress-strain relationships on tensile and compressive strengths was analyzed, as well as the influence of the use of damage variables. Three different stress-strain relationships on concrete compressive strength were tested, and another three on concrete tensile strength, distinguished by the crack opening displacement. The obtained results were calibrated with the experimental results of four experimental models, and, next, the proposed calibration was compared with twelve other experimental results. Finally, the proposed parameters showed to be suitable to represent the structural behavior of bolted shear connectors applied in force transfer in concrete-filled composite columns.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.