Abstract

<p>The current design codes for punching shear resistance of flat slabs are based on empirical formulations derived from test results of isolated slab-column connections, where the compressive membrane action was ignored. Testing continuous slab systems is very uneconomical and in most cases not possible. In this paper, finite element analyses (FEA) are performed to investigate the structural performance of continuous slabs. A previously tested and analysed isolated slab with larger in-plane dimensions and different boundary conditions is considered. The FEA results indicate that the shear capacity of the continuous slab is much higher compared to the capacity of the isolated slab. The numerical models are used to examine the effect of low reinforcement ratio in the response of the continuous slabs. Finally, a comparison between analytical results and code provisions indicates the conservatism of the design codes.</p>