Abstract
Although beam to beam joints are a critical part of steel structures and connection strength varies with temperature considerably, regrettably very few works have been conducted under elevated temperature conditions on end plate moment connection. The strength and stiffness properties degrade with increase of temperature. This paper presents an investigation of a bolted extended end-plate beam to beam joint subjected to variation of temperature. 20°C, 204°C, 316°C, 427°C, 649°C temperatures were considered for finite element analysis and their effects on end-plate moment connection were discussed. It has been found that with the increase of temperature, end plate thickness does not vary but stiffness of end plate reduces considerably. Finally, the effects of the changes of different beam parameters on the end-plate moment connection were discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.