Abstract
Based on the test of abnormal exterior joints of Steel Reinforced Concrete (SRC) column and Reinforced Concrete (RC) beam, the paper analyzed the influence on crack resistance behavior by ABAQUS, of the eccentricity of column section, the steel ratio of the joints zone, the concrete strength and the axial compression ratio and so on. The study indicates that the anti-crack capacity of the joints mainly depends on “the minor joint zone”. Based on the computing unit of minor joint core zone, the calculating formula of anti-crack capacity of the joints is deduced.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.