Abstract

The ABAQUS finite element software is used to calculate the vertical bearing capacity of single piles in Tianjin, and the finite element results are compared with the data gained through the in-situ static load pile foundation tests. It is found that the Young’s modulus of the soil at the bottom of the pile could have a important role in improving the vertical bearing capacity of single piles.