Abstract
Early childhood caries (ECC) involve extensive coronal tooth structure loss, and tooth reconstruction remains highly challenging. To fulfill preclinical assessment, the present study investigated the biomechanics of non-restorable crownless primary molars that were restored by stainless steel crowns (SSC) using different composite core build-up materials. Computer-aided design-integrated 3D finite element and modified Goodman fatigue analyses were performed to determine stress distribution, risk of failure, fatigue life and dentine-material interfacial strength for the restored crownless primary molars. A dual-cured resin composite (MultiCore Flow), a light-cured bulk-fill resin composite (Filtek Bulk Fill posterior), a resin-modified glass-ionomer cement (Fuji II LC) and a nano-filled resin-modified glass-ionomer cement (NRMGIC; Ketac N100) were used as core build-up composite materials in the simulated models. The finite element analysis showed that types of core build-up materials affected the maximum von Mises stress only in the core materials (p-value = 0.0339). NRMGIC demonstrated the lowest von Mises stresses and revealed the highest minimum safety factor. The weakest sites were along the central grooves regardless of type of material, and the ratio of shear bond strength to maximum shear stress at the core-dentine interface of the NRMGIC group was lowest among the tested composite cores. However, all groups provided lifetime longevity from the fatigue analysis. In conclusion, core build-up materials differentially influenced the von Mises stress (magnitude and distribution) and the safety factor in crownless primary molars restored with core-supported SSC. However, all materials and the remaining dentine of crownless primary molars provided lifetime longevity. The reconstruction by core-supported SSC, as an alternative to tooth extraction, may successfully restore non-restorable crownless primary molars without unfavorable failures throughout their lifespan. Further clinical studies are required to evaluate the clinical performance and suitability of this proposed method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.