Abstract

The U.S. Army Corps of Engineers (USACE) currently operates and maintains approximately 193 commercially active lock sites with 239 locks and dams spanning nearly 12,000 miles. These networks of water channels are used to transport 600 million tons of domestic cargo, generating $405 billion in revenue annually. Nearly 60% of these structures in operation are over 50 years old and have reached design life. A failure of the miter gates could result in a major negative impact on the economy and on the ability to maintain flood control. Administrators need recommendations to better prioritize maintenance and repair of the USACE miter gates. This work investigated the influence of miter gate’s quoin block degradation on load transfer to the pintle and/or pintle connections. Results of finite element analysis are reported for the quoin block degradation simulated levels of 0%, 25%, 50%, and 75%. The parametric study shows the overstressed regions are the pintle neck and bolt-hole regions. To improve pintle designs so they may better mitigate detrimental environmental based deterioration effects, this work recommends (1) increasing the thickness of the bolt-hole connection region and (2) adding ribbing reinforcement around the neck area of the pintle.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call