Abstract
Infra-acetabular screws have been described to increase the fixation strength of acetabular fractures with separation of the columns. Previous studies were based on the simulation of the anterior column fractures without modelling the biomechanical effect of the screw in the posterior column fractures. The purpose of this study was to compare the stability of different internal fixation models of posterior column fracture and to provide a theoretical basis for the clinical application of infra-acetabular screws. Five internal fixation models of acetabular posterior column fracture were simulated using five implants, including one reconstruction plate (PCP model), one posterior column screw (PCS model), one infra-acetabular screw (PIS model), one infra-acetabular screw and one reconstruction plate (PIS + PCP model), and one infra-acetabular screw and one posterior column screw (PIS + PCS model). After meshing, material parameter, and boundary condition settings, a vertical downward load of 500N was applied on the surface of the sacrum. To evaluate the biomechanical properties, the stress distribution and von Mises peak stress were recorded and analyzed, and the displacement distributions of the upper and lower fracture surfaces were compared. In model PCP, the maximum stress of the plate is 71.952MPa; in model PCS, the maximum stress of the screw is 52.740MPa; in model PIS, the maximum stress of the screw is 68.985MPa; in model PIS + PCP, the maximum stress of the plate is 64.695MPa and the maximum stress of the screw is 39.679MPa; and in model PIS + PCS, the maximum stress of the posterior column screw is 48.197MPa and the maximum stress of the infra-acetabular screw is 65.201MPa. The maximum stresses of implants are all located on the fracture surfaces. The average displacement differences of the upper and lower fracture surfaces are compared as follows: model PIS + PCS (0.03503mm) < model PIS + PCP (0.08205mm) < model PCP (0.10096mm) < model PCS (0.19007mm) < model PIS (0.23546mm). With sufficient biomechanical stability, infra-acetabular screws can be used as a supplementary fixation for the treatment of acetabular posterior column fractures. It is recommended to fix the fracture by the combined application of the infra-acetabular screw and posterior column screw.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.