Abstract

To establish finite element models of different preserved angles of osteonecrosis of the femoral head (ONFH) for the biomechanical analysis, and to provide mechanical evidence for predicting the risk of ONFH collapse with anterior preserved angle (APA) and lateral preserved angle (LPA). A healthy adult was selected as the study object, and the CT data of the left femoral head was acquired and imported into Mimics 21.0 software to reconstruct a complete proximal femur model and construct 3 models of necrotic area with equal volume and different morphology, all models were imported into Solidworks 2022 software to construct 21 finite element models of ONFH with LPA of 45°, 50°, 55°, 60°, 65°, 70°, and 75° when APA was 45°, respectively, and 21 finite element models of ONFH with APA of 45°, 50°, 55°, 60°, 65°, 70°, 75° when LPA was 45°, respectively. According to the physiological load condition of the femoral head, the distal femur was completely fixed, and a force with an angle of 25°, downward direction, and a magnitude of 3.5 times the subject's body mass was applied to the weight-bearing area of the femoral head surface. The maximum Von Mises stress of the surface of the femoral head and the necrotic area and the maximum displacement of the weight-bearing area of the femoral head were calculated and observed by Abaqus 2021 software. The finite element models of ONFH were basically consistent with biomechanics of ONFH. Under the same loading condition, there was stress concentration around the necrotic area in the 42 ONFH models with different preserved angles composed of 3 necrotic areas with equal volume and different morphology. When APA was 60°, the maximum Von Mises stress of the surface of the femoral head and the necrotic area and the maximum displacement of the weight-bearing area of the femoral head of the ONFH models with LPA<60° were significantly higher than those of the models with LPA≥60° ( P<0.05); there was no significant difference in each index among the ONFH models with LPA≥60° ( P>0.05). When LPA was 60°, each index of the ONFH models with APA<60° were significantly higher than those of the models with APA≥60° ( P<0.05); there was no significant difference in each index among the ONFH models with APA≥60° ( P>0.05). From the perspective of biomechanics, when a preserved angle of ONFH is less than its critical value, the stress concentration phenomenon in the femoral head is more pronounced, suggesting that the necrotic femoral head may have a higher risk of collapse in this state.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call