Recently, finite control set model predictive control (FCS-MPC) has been successfully applied in the grid-tied inverter with the LCL filter. However, to achieve active damping and grid synchronization, many sensors are required, increasing cost, and complexity. In addition, a considerable computational delay should be addressed when it is experimentally implemented, which may degrade the performance of the overall system. In order to reduce the number of sensors, eliminate the computational delay, and enhance the control reliability of the system, a novel FCS-MPC strategy with merely grid-injected current sensors is proposed, which contains four compositions: virtual flux observer, state observer, delay compensation, and FCS-MPC algorithm based on estimations. A 3-kW/3-phase/110-V experimental platform is established to validate that utilizing the proposed observations-based control method with only grid-injected current sensors is capable to obtain satisfactory performance of grid synchronization and high-quality grid-injected current both under balanced and unbalanced grid voltage condition.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.