Abstract

The goal of this study was to investigate repetitive finger tapping patterns in patients with Parkinson’s disease (PD), progressive supranuclear palsy–Richardson syndrome (PSP-R), or multiple system atrophy of parkinsonian type (MSA-P). The finger tapping performance was objectively assessed in PD (n=13), PSP-R (n=15), and MSA-P (n=14) patients and matched healthy controls (HC; n=14), using miniature inertial sensors positioned on the thumb and index finger, providing spatio-temporal kinematic parameters. The main finding was the lack or only minimal progressive reduction in amplitude during the finger tapping in PSP-R patients, similar to HC, but significantly different from the sequence effect (progressive decrement) in both PD and MSA-P patients. The mean negative amplitude slope of −0.12°/cycle revealed less progression of amplitude decrement even in comparison to HC (−0.21°/cycle, p=0.032), and particularly from PD (−0.56°/cycle, p=0.001), and MSA-P patients (−1.48°/cycle, p=0.003). No significant differences were found in the average finger separation amplitudes between PD, PSP-R and MSA-P patients (pmsa-pd=0.726, pmsa-psp=0.363, ppsp-pd=0.726). The lack of clinically significant sequence effect during finger tapping differentiated PSP-R from both PD and MSA-P patients, and might be specific for PSP-R. The finger tapping kinematic parameter of amplitude slope may be a neurophysiological marker able to differentiate particular forms of parkinsonism.