Abstract

Objective: To determine whether the recommended method of locating finger position for chest compression in infant cardiac arrest can cause pressure on the abdomen or xiphisternum. Design: The length from the inter-nipple line to the xiphisternum was calculated in 30 infants. These lengths were compared with the finger position achieved by 30 adults, using the recommended method, on templates of infant chests. Results: The mean infant lower sternal length was 2.3 cm (95% CI 1.6). The mean distance covered by the adults fingers was 4.4 cm (95% CI 0.9). Conclusion: If any infant in this study had chest compressions performed by any of the adults, using the recommended method, pressure would be exerted on the xiphisternum or abdomen. We suggest changing the method of locating finger position, to one using sternal anatomy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.