Abstract

The aim of this experimental cadaver study was to investigate which kinds of lesions could occur in jam events between the glass and seal entry of power-operated motor vehicle side door windows at two different closing forces.Ten hands of fresh cadaver specimens were used. Three different hand positions chosen to simulate real events in which a finger is jammed between the glass and seal entry of the window of a current motor vehicle were examined. The index, middle, ring, and little finger of each hand were separately jammed both at the proximal and distal interphalangeal joint at closing forces of 300 and 500N with a constant window glass closing speed of 10cm/s. Macroscopically visible injuries were documented and radiographs of all fingers were obtained in two standard planes.At a closing force of 300N, contusion marks of the skin, palmar joint instabilities and superficial skin lesions occurred, whilst at 500N superficial skin lesions, superficial and deep open crush injuries, and fractures were observed. The results of this study experimentally demonstrate the kinds of finger injuries that could be expected in real jam events between the glass and seal entry in automatic power-operated windows.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.