Abstract

Routine tests that measure the concentration of electrolytes in serum are needed for diagnosis and management of renal, endocrine, acid-base, water balance and other conditions such as screening D- and A-vitamin disorders, kidney insufficiency, bone diseases and leukaemia. The diagnostic concentration ranges for many such markers are narrow, requiring reference methods with small uncertainty. Serum concentration of total selenium (Se) is important in health studies but there is increasing interest in the speciation of selenium compounds in clinical samples such as serum and individual Se- Species are bio-indicators of Se status.The last CCQM IAWG key comparison for elements in the clinical area (CCQM-K14: Ca in human serum) was organized in 2003 and the previous key comparison (CCQM-K60) for Se and Se species used a wheat flour sample. Therefore, the CCQM IAWG agreed that CCQM-K107 and a parallel pilot study CCQM-P146 should be carried out. The candidate human serum sample used for both CCQM-K107 and P146 is of high complexity and contains approximately 1000-fold lower concentrations of selenium methionine (SeMet) than those encountered in the CCQM-K60 wheat flour. This significantly broadens the scope and degree of difficulty of earlier measurements in this field.A total of eleven institutes participated in CCQM-K107 (11 participants for total elements and 7 for SeMet). The performance of the majority of the K107 participants for all the measurands was very good, illustrating their ability to obtain accurate results for analytes such as electrolytes at mg kg-1 level, essential elements at µg kg-1 level and selenium species at µg kg-1 level in a complex biological fluid. The range of agreement between participants was within the interval of ± 0.1% for Ca and up to ± 1.8% for Fe.CMC claims based on total elements in this study may include other elements with similar core competencies (e.g. Se, Cu, Zn) in a wide range of biological materials (including liquids and solids) at a similar level of performance using the same measurement technique applied in CCQM-K107 provided that there are no additional factors (e.g. blank or dissolution issues). CMC claims based on SeMet measurements in this study may be applied to other biological matrices (e.g., tissues) provided that the concentration range is similar and due diligence is taken to ensure an appropriate extraction process is achieved and species specific spikes are available for quantitation by isotope dilution. Indeed, having accepted such conditions, application to quantitation of other organometallic species and other elements in similar matrices should be possible with the same level of performance.Main textTo reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.