Abstract

Filterability of erythrocytes through small (3 μ) pores decreases with decreasing osmolarity of suspension medium because of hypo-osmotic swelling of cells. After appearance of lytic pores, erythrocyte filterability increases for some time, while after recovery of membrane integrity it decreases again. We suggest filtration method for studies of the kinetics of hypo-osmotic lytic pores closure. The dynamics of changes in erythrocyte filterability was studied in 2 patients with paroxysmal nocturnal hemoglobinuria and 6 donors (Ht 0.01%, Na phosphate buffer 5 mM, pH 7.4, 35 mOsm, 24°C). The method can be used for studies of erythrocyte membrane characteristics in various diseases and for evaluation of the membranotropic effects of drugs, infusion media, hemolysins, ethanol, etc.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.