Abstract

In this study, we conducted water hammer experiments in the tube which was periodically supported by various numbers of clamps, named periodic structure, initiated by a projectile impact. The parts of the polycarbonate (PC) tube supported by 1-7 steel clamps make the tube stiffer and heavier than the original PC tube and are expected to cause a filtering effect of the frontal frequency components in the water hammer. According to our experimental observations, we confirmed that higher frequency components more than 1 kHz in the wave front were attenuated and the peak strains in circumferential direction of the tube were decreased 20% from the original PC tube. Moreover, we conducted numerical simulations of the water hammer wave similar to the experimental setup. Numerical results also revealed that frontal peak is attenuated 22% through periodic structure.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.