Abstract

In this paper, the transient IR-thermography method is used to investigate the effect of showerhead cooling on the film-cooling performance of the suction side of a turbine guide vane working under engine-representative conditions. The resulting adiabatic film effectiveness, heat transfer coefficient (HTC) augmentation, and net heat flux reduction (NHFR) due to insertion of rows of cooling holes at two different locations in the presence and absence of the showerhead cooling are presented. One row of cooling holes is located in the relatively high convex surface curvature region, while the other is situated closer to the maximum throat velocity. In the latter case, a double staggered row of fan-shaped cooling holes has been considered for cross-comparison with the single row at the same position. Both cylindrical and fan-shaped holes have been examined, where the characteristics of fan-shaped holes are based on design constraints for medium size gas turbines. The blowing rates tested are 0.6, 0.9, and 1.2 for single and double cooling rows, whereas the showerhead blowing is maintained at constant nominal blowing rate. The adiabatic film effectiveness results indicate that most noticable effects from the showerhead can be seen for the cooling row located on the higher convex surface curvature. This observation holds for both cylindrical and fan-shaped holes. These findings suggest that while the showerhead blowing does not have much impact on this cooling row from HTC enhancement perspective, it is influential in determination of the HTC augmentation for the cooling row close to the maximum throat velocity. The double-row fan-shaped cooling seems to be less affected by an upstream showerhead blowing when considering HTC enhancement, but it makes a major contribution in defining adiabatic film effectiveness. The NHFR results highlight the fact that cylindrical holes are not significantly affected by the showerhead cooling regardless of their position, but showerhead blowing can play an important role in determining the overall film-cooling performance of fan-shaped holes (for both the cooling row located on the higher convex surface curvature and the cooling row close to the maximum throat velocity), for both the single and the double row cases.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.