Abstract
In this study, computational simulations were made using ANSYS CFX to predict the improvements in film cooling performance by using novel upstream steps. There are twenty-one novel steps consisting of three groups are tested. The first group consists of a rectangular step with different tilt angles. The second group consists of a normal rectangular step with and without segmentation. The third group consists of curved steps with and without segmentation. Optimizing the curved steps dimensions is performed. The film cooling effectiveness (η) of twenty-one novel steps were investigated and compared with experiment. Velocity profiles, pressure coefficient profiles and turbulent kinetic energy contours were discussed. Blowing ratios in the range (0.5, 1, 1.5 and 2) were investigated. Results indicate that the best novel step is the curved step with width (W/8) and the average values of film cooling effectiveness is increased to 138.8% compared with the experiment.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.