Abstract

The film condensation of a downward flowing R-113 vapor on in-line bundles of horizontal finned tubes was experimentally investigated. The test sections were 3×15 bundles with or without two rows of inundation tubes at the top. Two tubes with flat-sided fins and four tubes with three-dimensional fins were tested. Heat transfer measurements were carried out on a row-by-row basis. The effect of the vapor velocity on the finned tube bundles was considerable smaller than the case of a smooth tube bundle. The decrease of the heat transfer coefficient due to the condensate inundation was small for tubes with flat-sided fins, while a considerable decrease was observed for tubes with three-dimensional fins. A tube with flat-sided fins of a small fin pitch (0.5 mm) showed the best heat transfer performance over the range of film Reynolds number tested (<2 500).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.