Abstract
Film condensation was considered for upward steam flow at the atmospheric pressure. The experimental data were obtained inside a vertical duralumin tube with the internal diameter of 200mm and roughness height of 0.14mm. The film Reynolds numbers and vapor Reynolds numbers were varied within the range of 1–16 and 280–3460, respectively. The obtained experimental data were lower than classical Nusselt prediction. The suggested correlation for the Nusselt number agrees the most of the data within 20%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.