Abstract
Field trial results of a 5 W all-fiber broadband supercontinuum (SC) laser covering the short-wave infrared (SWIR) wavelength bands from ~1.55 to 2.35 μm are presented. The SC laser is kept on a 12 story tower at the Wright Patterson Air Force Base and propagated through the atmosphere to a target 1.6 km away. Beam quality of the SC laser after propagating through 1.6 km is studied using a SWIR camera and show a near diffraction limited beam with an M(2) value of <1.3. The SC laser is used as the illumination source to perform spectral reflectance measurements of various samples at 1.6 km, and the results are seen to be in good agreement with in-lab measurements using a conventional lamp source. Spectral stability measurements are performed after atmospheric propagation through 1.6 km and show a relative variability of ~4%-8% across the spectrum depending on the atmospheric turbulence effects. Spectral stability measurements are also performed in-lab and show a relative variability of <0.6% across the spectrum.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.