Abstract
Four representative Illinois Department of Transportation (IDOT) highway sign support trusses were evaluated analytically and in the field to assess their design load capacity and fatigue resistance when subjected to wind loading. The three overhead span bridge and one cantilever welded aluminum truss structures were instrumented for static and dynamic field testing with strain gages and accelerometers to collect structural behavior data when subjected to manual excitation, wind loading, and truck gust excitation. Companion analytical models were developed and calibrated to represent the structures in the field, after which these were then used to assess the response of the trusses at full design wind loads. Current IDOT and AASHTO highway sign support structure design loading and resistance approaches with respect to both strength and fatigue have been critically assessed in light of the analyses and field test results, with recommendations made for improving future designs.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.