Abstract
This study is to evaluate the sampling bias of a new cyclone (Tsai et al. 1999) and a 10 mm nylon cyclone under field sampling conditions. Both cyclones were operated at the optimum flow rate of 1.7 L / min. The Marple personal cascade impactor was used to measure the particle size distributions, which were used to calculate the reference RPM (Respirable Particulate Matter) concentrations according to the new ACGIH criteria. A wind tunnel was used in the field to ensure uniform particle concentration and wind speed across the tested cyclones and impactors in the working section. The wind speed, which was varied from 0.8 to 2.3 m / s, was kept constant in the wind tunnel. Near the packaging area of a glazing-making factory (mass median aerodynamic diameter, or MMAD: 11.1 Um), the average ratio of the RPM concentrations measured by the cyclones to the standard RPM concentrations was found to be 1.20 and 1.10 for the 10 mm nylon and the new cyclone, respectively. Near the packaging area of a lead powder fact...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.