Abstract

This paper presents a study of the self-siphon sediment cleansing set (SSCS), a system designed to remove sediment from the deep combined sewer overflow (CSO) chamber during dry-weather periods. In order to get a better understanding of the sediment removal effectiveness and operational conditions of the SSCS system, we carried out a full-scale field study and comparison analysis on the sediment depth changes in the deep CSO chambers under the conditions with and without the SSCS. The field investigation results demonstrated that the SSCS drains the dry-weather flow that accumulated for 50-57 min from the sewer channel to the intercepting system in about 10 min. It is estimated that the bed shear stress in the CSO chamber and sewer channel is improved almost 25 times on average. The SSCS acts to remove the near bed solids with high pollution load efficiently. Moreover, it cleans up not only the new sediment layer but also part of the previously accumulated sediment.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call