Abstract
The findings from an investigation of GCL overlap for a GCL constructed as part of a 55 m long (3H:1V) composite side liner for a landfill cell after 18 months exposure in Melbourne Australia are reported. It is concluded that the nominated minimum overlap of 300 mm was appropriate to achieve the design intent for the particular GCL examined. It is also concluded that for the exposure to which the GCL was subjected, the particular GCL experienced 50–80 mm of shrinkage during 18 months of exposure when the geomembrane was covered by a 5 mm thick off-white geotextile protection layer.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.