Abstract
During compressor operation, vibration of the connecting pipeline often occurs which potentially has an impact on safety. Field vibration measurements are carried out on a pipeline for a centrifugal compressor, and the vibration waveform and spectrum characteristics are obtained. Numerical studies are conducted to investigate the relationship between the natural frequency of the pipeline and the fluid excitation frequencies. These numerical results are verified by comparison with the field measurement values, which shows that the numerical method can be useful for engineering applications. Some preliminary conclusions are drawn from the results of the field measurements and the numerical simulation. Pressure fluctuations spread through the pipeline over an appreciable distance. The sensitive frequencies of the pipeline vibration are determined, and the fundamental causes of the flow induced vibration revealed. Accordingly, the pipeline structure can be modified to reduce the vibration and ensure the safety of the equipment and the pipeline.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.