Abstract

This study measured and estimated the subway vent shaft air flow rate induced by moving trains in the tunnel. This work estimated the flow rate via the tunnel structure and train movement to determine the quantitative effect of vent shafts as air purification systems of natural ventilation to improve the air quality management of a subway. The amount of air suctioned into the tunnel is significantly larger than that vented from the tunnel. Thus, placing vent shafts near subway stations is desirable for natural ventilation systems. Experimental approaches to measure train-induced flow rates have not yet been published. Results of this study provide useful fundamental data to study the natural ventilation in a subway. Therefore, this study suggested the significant design factors required to control indoor air quality in a subway.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.