This presentation introduces hearing protection fit testing on over 1000 workers in 6 different factories, each with different hearing conservation practices in China. The 3MTM E-A-RfitTM Dual-Ear validation system was used to measure the Personal Attenuation Rating (PAR), on three different types of Hearing Protection Devices (HPDs), including a foam earplug, a premolded earplug, and a headband earmuff at the work site. A follow up visit to repeat fit-testing was conducted approximately 6 months after the initial visit. Field attenuation of HPDs obtained by workers’ and the effects of training toward improving the attenuation were observed. In addition, PARs for the Peltor™X4A earmuff users were obtained at several points throughout the work shift to capture different fits. Result shows that there is wide variability in PARs and poor agreement between PAR and labelled noise attenuation ratings obtained from laboratory measurement. Hearing protection fit testing is essential to verify the sufficiency of a...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.