Abstract

Pushed by social demands, China has continuously developed its low-medium speed maglev transportation systems in recent decades. However, with the increase of the running mileage of the train, high frequency vibration of suspension frame gradually appears. In this paper, a method to analyze the high frequency vibration of suspension frame by detecting the current of traction motor is proposed. Field measurements of suspension frame vibration and traction motor current of low-medium maglev train were conducted on a maglev line that has been commercially put into operation. The test results show that the speed of the measured maglev train was closely correlated with vibration accelerations of the suspension frame in three directions, but as the speed increased, the influence it imposed on the suspension frame vibration waned. The dominant frequency of traction motor resultant current was consistent with the dominant frequency of the suspension frame vibration acceleration. The switching frequency of traction inverter was the main cause of high frequency vibration of suspension frame.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.