Abstract

BackgroundA newly designed electrostatic precipitator (ESP) in tandem with Versatile Aerosol Concentration Enrichment System (VACES) was developed by the University of Southern California to collect ambient aerosols on substrates appropriate for chemical and toxicological analysis. The laboratory evaluation of this sampler is described in a previous paper. The main objective of this study was to evaluate the performance of the new VACES-ESP system in the field by comparing the chemical characteristics of the PM collected in the ESP to those of reference samplers operating in parallel.ResultsThe field campaign was carried out in the period from August, 2007 to March, 2008 in a typical urban environment near downtown Los Angeles. Each sampling set was restricted to 2–3 hours to minimize possible sampling artifacts in the ESP. The results showed that particle penetration increases and ozone concentration decreases with increasing sampling flow rate, with highest particle penetration observed between 100 nm and 300 nm. A reference filter sampler was deployed in parallel to the ESP to collect concentration-enriched aerosols, and a MOUDI sampler was used to collect ambient aerosols. Chemical analysis results showed very good agreement between the ESP and MOUDI samplers in the concentrations of trace elements and inorganic ions. The overall organic compound content of PM collected by the ESP, including polycyclic aromatic hydrocarbons (PAHs), hopanes, steranes, and alkanes, was in good agreement with that of the reference sampler, with an average ESP -to -reference concentration ratio of 1.07 (± 0.38). While majority of organic compound ratios were close to 1, some of the semi-volatile organic species had slightly deviated ratios from 1, indicating the possibility of some sampling artifacts in the ESP due to reactions of PM with ozone and radicals generated from corona discharge, although positive and negative sampling artifacts in the reference filter sampler cannot be ruled out.ConclusionThe very good overall agreement between ESP and reference samplers makes it an attractive alternative to filters and biosamplers for chemical and toxicological evaluation of PM properties, including the possibility of conducting direct in vitro cell exposures. Moreover, the concentration enrichment of ambient aerosols by the VACES allows for short-term exposure studies, which preserve cell viability and enable studies to PM generated from specific sources and-or formation mechanisms in the atmosphere.

Highlights

  • A newly designed electrostatic precipitator (ESP) in tandem with Versatile Aerosol Concentration Enrichment System (VACES) was developed by the University of Southern California to collect ambient aerosols on substrates appropriate for chemical and toxicological analysis

  • A newly designed Electrostatic Precipitator (ESP) in tandem with a Versatile Aerosol Concentration Enrichment System (VACES) was tested in an urban environment to validate its performance for collecting ambient particles for potential applications in the field of toxicology, including direct in-vitro cell exposure

  • To investigate the performance of the ESP, a reference sampler was deployed in parallel to collect concentration-enriched aerosols, and a micro-orifice uniform deposit impactor (MOUDI) sampler was used to collect ambient aerosols

Read more

Summary

Introduction

A newly designed electrostatic precipitator (ESP) in tandem with Versatile Aerosol Concentration Enrichment System (VACES) was developed by the University of Southern California to collect ambient aerosols on substrates appropriate for chemical and toxicological analysis. The main objective of this study was to evaluate the performance of the new VACES-ESP system in the field by comparing the chemical characteristics of the PM collected in the ESP to those of reference samplers operating in parallel. The same system has been used in tandem with a liquid particle collector (BiosamplerTM, SKC Inc, Eighty-four, PA, USA) to collect in-vitro samples into aqueous suspensions for indirect cell exposure. This novel system cannot provide PM for direct cell exposures

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.