Abstract

This paper presents the key observations and conclusions from the evaluation of an innovative "loose-fit" composite, post-tensioned concrete wing-girder bridge proposed for an elevated interstate highway expansion in an urban environment. The evaluation program included both testing to destruction of a 1/2-scale model of a partial span as well as construction monitoring and field testing at service load levels of a full-scale prototype two-span bridge. Results of both construction measurements and loading tests were compared with analytical predictions. Laboratory tests showed the composite behavior of the wing-girder joint to be fully effective and a high level of load transfer between wings to be present. Recommendations for modification of the prototype design are made to improve constructibility, durability, structural performance, and economy. Key words: box girder, bridge, post-tensioned, prestressed concrete, reinforcement, stresses, temperature, tendons.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.