Abstract

Performance of superconducting cavities are investigated with field emission effect and x-ray detection. Conducting particles and surface curvature can cause field emission from the surface of the superconducting Nb cavity. The field emission makes the local temperature increase and the quality factor decrease. Vertical test is performed for half-wave resonator (HWR) cavities. The vertical test facilities are introduced and the quality factors are measured for the half-wave resonator (HWR) cavities. The quality factors of the cavities decrease as the x-ray are increased. The surface resistance and x-ray generation of the cavity can be fitted well with the field emission theory. The quality factor for the half-wave resonator (HWR) cavities decreases linearly with the field enhancement factor for x-ray generation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.