Abstract

This article is to discuss a cold standby system which consists of l series working components and n − 1 independent cold standby components. Suppose that the component follows geometric distribution. The precise Fiducial lower confidence limit for system reliability is obtained, when only a parameter is unknown. And when all of the parameters are unknown, a method is offered to resolve the Fiducial approximate lower confidence limit for system reliability. At the same time Monte Carlo simulation is carried out to verify the conclusions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.