Abstract

Colloidal assemblies represent a versatile and cost efficient way to generate surface patterns at micron and sub-micron length scales. Chemical modification of the assemblies can be utilized to study the influence of different surface chemistries on cellular responses with high lateral resolution. In this study, single and binary colloidal assemblies were made using different sizes of particles. An allylamine plasma polymer (ALApp) layer was deposited on the top of the assemblies to provide a uniform surface chemistry. Cellular responses toward unmodified and ALApp-coated assemblies was evaluated using L929 fibroblasts. Cells showed smaller spreading area on both single and binary assemblies compared to flat control. Cell size was dependent on the particle size or combination. This effect can be compensated by different degrees after the ALApp coating. These results will find application in the development of new cell culture coatings through the combined use of colloidal assembles and plasma polymer coatings.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.