Abstract

The interactions of a biomaterial with tissues must be determined for the material to be fully compatible with the body for a long time. The tissue and environment where the material is implanted are highly affected by its content. Titanium-6Aluminum-4Vanadium is widely used in orthopedics and dentistry. Recently, Titanium-6Aluminum-7Niobium alloys have been studied because of Titanium-6Aluminum-4Vanadium toxicity, which may be caused by vanadium. The aim of this study was to determine whether Titanium-6Aluminum-4Vanadium and Titanium-6Aluminum-7Niobium affect fibroblast cell proliferation, mineralization, and collagen production and whether they change the expression of type 1 collagen and fibronectin genes. It was determined that the niobium-containing alloy increased cell proliferation and calcium mineralization compared with the vanadium-containing alloy (p < 0.05). However, the alloys did not cause changes in the expression of collagen type 1 or fibronectin in cells. The collagen content of the cells on the niobium-containing alloy was lower than that on both the vanadium-containing alloy and tissue culture plate surface (p < 0.05). The niobium-containing alloy was found to be superior to the vanadium-containing alloy in terms of cell proliferation and calcium mineralization. Furthermore, neither vanadium-containing alloy nor niobium-containing alloy implant materials altered gene expression. Although both alloys are considered compatible with bone tissue, it should be considered whether they are also biocompatible with fibroblast cells.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call