Abstract

Very little has been published to indicate the quantity of fibrinogen in cryoprecipitates. We assayed 88 preparations from five blood banks for factor VIII(AHF) and fibrinogen to assess whether the AHF assay can predict the fibrinogen content. Cryoprecipitate was considered to be consistent with FDA standards with 80 units of factor VIII/bag (40% yield from 200 ml plasma). Fibrinogen was considered adequate if 200 mg were recovered (40% yield, 200 ml plasma, normal range 150--350 mg/dl). The mean AHF was 145 units/bag and fibrinogen. In 64/88 bags, the fibrinogen and AHF were concordant, but in 24/88 bags the results were discordant. Although it appears safe to conclude that a bag of cryoprecipitate will average 250 mg fibrinogen, adequate control may require separate assays for fibrinogen.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.